Kategorie: g_kuehlen_en
Crankcase cooler with forced cooling and re-cooling unit
Also this crankcase cooler is based on the principle of a tunnel cooler with special flowing nozzles.
By means of a conveying system, provided by the customer, the crankcases are brought to the unit in transport cups. With a converter there they are going to be distributed to 12 cooling conveying bands. On the other end of the cooler the crankcases of the 12 cooling conveying bands are re-combined again with a second converter. They are forwarded to the finishing lines. The complete cooler consists of two of these cooling units with 24 cooling sections in total. Additionally, the unit has a re-cooler for the cooling air, so that it can be driven in recirculated-air operation.
Technical data:
- Cooling tunnel: 24 pieces with each approx. 9m
- Types of castings: crankcasese with different versions of 3- & 4-cylinder double castings and 6-cylinder
- cycle time: 30 seconds
- Degree of automation: fully automated
- Loading/unloading: converter with belt conveyor