Separation of sticky components

Reference project

In order to protect the supplied systems from contamination and to optimize the service life of the individual components, filter systems are installed upstream. These can consist of standard bag filters with the appropriate filter class, as well as of specially designed systems, for example for the separation of sticky components.
To protect concentrators or other systems from contamination by dust, multi-stage filter systems are very frequently used. For cleaning approximately 34,000 m³/h, a police filter of filter class F9 is provided. As a rule, two further filter stages (G3 and M6) are installed upstream.